Prototype of Battery Monitoring System for Gasoline Vehicle using Microcontroller Module
Heru Supriyono1, Raden Adrian Rafli Prasetyo 1, Adi Sasono1, Mahmud Iwan Solihin2
Corresponding Author: Heru Supriyono


Question & Answer to the Presentation

Question from Mr. Andi Widiyanto
2022.12.21 14:18:18

interesting research
a few years ago, a part of my research was also monitoring battery voltage. The
problem with the monitoring system is during the charging process. the sensor
reading the voltage cannot distinguish between the actual battery voltage and the
charger voltage. Please share your knowledge and experience to solve my problem
Thank you very much
Replies:

Reply from Mr. Heru Supriyono
2022.12.21 14:28:13

Dear Mr. Andi Widiyanto,

Thank you very much for your comment,

The research on battery charging is very interesting and very demanded especially
since currently there are mass shifting from gasoline based to electric vehicle. I also
have been experiencing the same problem. However, just from pragmatical view, I
put two sensors namely sensors from the charger to the battery and afterwards
sensor from the battery to the loads.
Currently I am still studying on this matter.

Thank you

Reply from Mr. Andi Widiyanto
2022.12.21 14:57:58

Ok, TQ
if you like, if you have succeeded in overcoming this problem, you can share it with
me andi.widiyanto@ummgl.ac.id
Thank you very much


Question from Ms. Mentari Putri Jati
2022.12.21 14:05:54

How many data for the experiment result? Could you give enough experiment data
for the analysis?
Replies:

Reply from Mr. Heru Supriyono
2022.12.21 14:43:15

Dear Ms Mentari Putri Jati

Thank you very much for your question.
For laboratory-scale experimentation we tested by using adjustable voltage
generator rampup from 0 to 15 volt (for voltage monitoring) and totally about 15
minutes for temperature monitoring.
For actual experimentation, it was about 4-5 minutes.

Thank you very much.