Experimental Study of the Effect of Cavities on the Load Capacity of Two-Way Reinforced Concrete Plates on Fixed Concrete Thickness A.Arwin Amiruddin4 Abstract The study aims to determine the effect of cavities on the load capacity of reinforced concrete slabs when compared to massive reinforced concrete slabs that have the same thickness, with the hope of reducing the structure^s weight and the use of concrete materials. The modified PVC pipes, as cavity formers, will be placed in the tensile area without reducing the flexural strength that is caused by the weak nature of concrete against tensile strength. The test is carried out on a full scale against 14 cm thick solid plates (PP-1), and hollow plates, which use modified PVC pipes (PB-2), with a cavity diameter of 7.6 cm that has the same thickness. The test uses joint supports on all four sides and the loading pattern is evenly distributed. All slabs are made, on the spot, of cast concrete with the same size and distance between the reinforcement. PVC hollow plate (PB-2) has the same effective thickness as solid plate but has 14% less concrete volume. The maximum load capacity on the solid plate (PP-1) is 522.66 kN and on the hollow plate (PB-2) is 444.33 kN. The melting capacity on the solid plate (PP-1) is 373,515 kN and on the hollow plate (PB-2) is 325,935 kN. Initial crack load capacity on the solid plate (PP-1) is 19.5 kN and on the hollow plate (PB-2) is 16.75 kN Keywords: PVC Hollow Plate, Plate Thickness, Load Capacity Topic: Infrastructure |